ASA 0567 230/400V (50Hz) - ASA0567AA4A (2.2
kW)
Copyright 2012 asa hydraulik GmbH
A: - J: -
B: - K -
C: - L: 634 mm
D: - N: -
G: - W: -
100 200 300 400
0.400
0.800
1.200
1.600
2.000
Qp [l/min]
Pspez [kW/°C]
Cooling Performance*
100 200 300 400
0.600
1.200
1.800
2.400
3.000
Qp [l/min]
P [bar]
Pressure Drop
Order Number Motor Power Current Protection Level Rotation Air Flow Noise Level Weight
ASA0567AA4A 2.2 kW 5.15 A IP 55 1420 1/min 2.8 kg/s 88 db(A) 92.3 kg
Working pressure (static): 26 bar (370 PSI)
Radiator material: Aluminium
*Note - Cooling Performance
Copyright 2012 asa hydraulik GmbH
The cooling performance mentioned in this homepage is conservative and measured at a test bench according to asa test procedures
with oil type ISO VG 46 and presents a bases for your cooler selection regarding required cooling performance. Because there is no
standard test procedure, tests used by other manufacturers might have different results. Due to different environment conditions the
cooling performance can vary by +/- 15%.
Therefore we recommend all coolers be checked under the system operating conditions. This is also true for vibrations and mechanical
stress as well as for pressure peaks and thermal stress.
General tolerance according to DIN 2768-v.
The information contained in this homepage is intended to be used as a guideline only. Customers should always confirm the suitability
of the information and these products in their particular applications. ASA assumes no liability for any errors, commissions or misprints
and reserves the right to change products and details without prior notification.As we are constantly improving our products, the
characteristics, dimensions and weights can also change, although we do our best to incorporate these changes continually.
asa hydraulik GmbH
Prager Strasse 280
A-1210 Wien, Austria, Europe
Tel.: ++43 / 1 / 292 40 20
Fax: ++43 / 1 / 292 40 70
support@asahydraulik.com